We manufacture precast concrete beams with the following cross-sections:
Beams with rectangular cross-section
width 3M, 4M, 5M, 6M, 7M
height 5M, 6M, 7M, 8M, 9M, 10M, 11M, 12M
Modular measurement M is 100 mm. In the case of different dimensions, the conditions for manufacturing the beams must be specified.
Recommended cross-section dimensions are 400x600, 400x700, and 400x800.
Ledge beams
width 3M, 4M, 5M, 6M, 7M
height 5M, 6M, 7M, 8M, 9M, 10M, 11M, 12M
Low height prestressed beams (see also TEMPO substructure ET-3 0202-0073)
width 550, 650 (1-ledge beam width in the lower surface)
700, 800 (2-ledge beam width in the lower surface)
height 415 (EP5/265), 470 (EP4/320), 550 (EP4/400)
Ledge height 150 mm
I beams
flange width 3M, 4M, 5M
I talade koormusdiagramm:
HI beams ( I beams with ridge)
flange pitch 1:16
flange width 3M, 4M, 5M
The corners of the mould are 15x15 mm
Load diagram of HI beams
Technical data
Tolerances in normal classes (mm):
length ±15 or L/1000
height and width ±10
steel parts ±10
edge curvature ±10 or L/500
edge deviation from right angle ±10
edge surface deviation from vertical plane ±15
pre-elevation ±10 or L/500
ocation of openings ±20
fire resistance class: according to the project
Load diagram
Primary data of design work and consultation: drawing, normative loads, coefficients, support connections, fire resistance class, and exposure class.
Load diagrams have been compiled based on static load.
Compressive strength class of concrete B50 (corresponding to Finnish category K50).
50% of live load is constant load.
Graphs (H*B) are intended only for the initial selection of cross-section.